CRT | - Configuration and useful screen : 6 inch rectangular screen with internal graticule, 8X10div. (1div = 1cm) marking for measurement of rise time, 2mm subdivisions along the central axis. - Acceleration potential : +10.5kv approx.(ref. Cathode) - Phosphor : P31 - Focusing : provided - Trace rotation : provided - Intensity control : provided |
Z-AXIS INPUT(INTENSITY MODULATION) | - Input signal : positive going signal decreases +5Vp-p or more signal cases intensity noticeable modulation at normal intensity setting - Bandwidth : DC to 3.5MHz(-3dB) - Coupling : DC - Input impedance : 17~22kΩ typical - Maximum input voltage : 20V(DC + peak AC) |
VERTICAL DEFLECTION | - DC coupled(-3dB) : DC to 100MHz normal / DC to 20MHz magnified - AC coupled(-3dB) : 10Hz to 100MHz normal / 10Hz to 20MHz magnified - Modes : CH1, CH2, ADD, CHOP, ALT - Deflection factor (normal): 2mV/div. to 5V/div. in 11 calibrated steps of 1-2-5 sequence. Continuously variable between steps at least 1:2.5 X 5. - Accuracy : normal ±3% - Input impedance : approx. 1MΩ in parallel with 25pF - Maximum input voltage : direct 250V (DC + peak AC) - Input coupling : AC, GND, DC - Rise time : 3.5ns or less (17.5ns or less : 2mV/div.) - CH1 output : 20mV/div. into 50Ω / 50Hz to 30MHz(-3dB) - Polarity inversion : CH2 only - Signal delay : delay cable installed |
HORIZONTAL DEFLECTION | - Sweep mode : A, A int B, B, B triggered, X-Y - Time base A : 0.1㎲/div. to 0.5s/div. in 21 calibrated steps of 1-2-5 sequence uncalibrated continuous control between steps at least 1:2.5 - Hold-off time on time base A : variable with the hold-off control - Time base B : 0.1㎲/div. to 10㎲/div. in 7 calibrated steps of 1-2-5 sequence - Delay sweep on time base B: 1div. or less / 10 div. or more - Sweep magnification : 10 times (max. sweep rate : 10ns/div.) - Accuracy : ±3%, ±5%(1:10 probe) |
TRIGGER SYSTEM | - Accuracy : - Modes : AUTO, NORM, TV-V, TV-H - Source : INT, LINE, EXT - Coupling : AC - Slope : + or - - Sensitivity and frequency in AUTO, NORM 30Hz -10MHz : 0.48div. in INT / 200mVp-p in EXT - Sensitivity and frequency in AUTO, NORM 10MHz -100MHz : 1.5div. in INT / 600mVp-p in EXT - Sensitivity and frequency in ALT trigger 30Hz -10MHz : 1.5div. in INT - Sensitivity and frequency in ALT trigger 10MHz -10MHz : 1.5div. in INT - Maximum input voltage : 250V (DC + AC peak) |
X-Y OPERATION | - Sensitivity : same as vertical deflection for both X-axis(CH1) except accuracy ±5% in X-axis - Frequency and bandwidth : DC to 2MHz (DC coupling) / 10Hz to 2MHz (AC coupling) - X-Y phase difference : 3°or less as DC to 50kHz |
CALIBRATOR | - Probe adjustment : approx. 1kHz frequency, 0.5V(±3%) square wave with 50% duty ratio |
POWER SUPPLY | - Line voltage range : 100V(90-110V) with 250V 2A fuse, 120V(108-132V) with 250V 2A fuse, 220V(198-242V) with 250V 1A fuse or 230V(216-250V) with 250V 1A fuse - Line frequency : 50/60Hz - Power consumption : approx. 60WOTHERSz |
PHYSICALCHARACTERISTICS | - Weight : 9.6kg - Dimension : 320mm(W) X 140mm(H) X 430mm(L) |
OTHERS | - Accessories including : Operation manual, Spare fuse, Power cord - Optional accessories (sold separately) : Probe |
购买
类别:仪器仪表 > 电子测量仪器> 失真度测量仪
价格:8800.00元
关键词:
模拟示波器 OS-5100
- 基本信息
- 名称:模拟示波器 OS-5100
- 品牌:韩国LG-EZ
- 型号:OS-5100
- 仪器介绍
- 同类仪器
- 售后服务
- 如何购买
- 仪器介绍
- 同类仪器
- 售后服务
- 如何购买
- 仪器介绍
- 同类仪器
- 售后服务
- 如何购买
- 仪器介绍
- 同类仪器
- 售后服务
- 如何购买
浏览此仪器的用户还看过
- 模拟示波器 OS-5100点击量:8800 次
- 自动失真测试仪GAD-201G点击量:4400 次
- 功率计OPM37LAN点击量:0 次
特价促销的仪器仪表
- 福禄克可视红外测温仪VT04A市场价:¥6499.00促销价:¥3740.00
- 夜视仪(红外热像仪) Scout PS32市场价:¥35800.00促销价:¥26000.00
- 夜视仪(红外热像仪) Scout PS24市场价:¥23800.00促销价:¥17850.00
- MT4MAX红外测温仪MT4 MAX市场价:¥428.00促销价:¥300.00
- 接地电阻测试仪 MDOEL 4105AH市场价:¥2730.00促销价:¥1600.00
最近更新仪器仪表
- SEEK美国原装红外热像仪热感应手机热成像仪摄像夜视仪地暖热像仪 更新日期:2018-08-02
- 福禄克可视红外测温仪VT04A 更新日期:2018-08-02
- 德图testo755-1 - 电流电压通断测试仪 0590 7551 更新日期:2018-07-24
- 德图 testo 750-3 - 非接触式电压及导通测试仪0590 7503 更新日期:2016-05-31
- 德图testo 750-2 - 非接触式电压及导通测试仪 0590 7502 更新日期:2016-05-31