模拟示波器 OS-5060A

模拟示波器 OS-5060A

基本信息
名称:模拟示波器 OS-5060A
品牌:韩国LG-EZ
型号:OS-5060A
类别:仪器仪表 > 电子测量仪器> 模拟示波器
价格:6870.00
关键词:
分享到:
  • 仪器介绍
  • 同类仪器
  • 售后服务
  • 如何购买

CRT

- Configuration and useful screen :
   6 inch rectangular screen with internal graticule, 8X10div.(1div = 1cm)
  marking for measurement of rise time, 2mm subdivisions along the central
  axis.
- Acceleration potential : +10kv approx.(ref. Cathode)
- Phosphor : P31
- Focusing : provided
- Trace rotation : provided
- Intensity control : provided
Z-AXIS INPUT(INTENSITY MODULATION)
- Input signal : positive going signal decreases +5Vp-p or more signal cases
  intensity noticeable modulation at normal intensity setting
- Bandwidth : DC to 2MHz(-3dB)
- Coupling : DC
- Input impedance : 20kΩ - 30kΩ typical
- Maximum input voltage : 30V(DC + peak AC)
    VERTICAL
    DEFLECTION
- DC coupled(-3dB) : DC to 60MHz normal / DC to 7MHz magnified
- AC coupled(-3dB) : 10Hz to 60MHz normal / 10Hz to 7MHz magnified
- Modes : CH1, CH2, ADD, DUAL(CHOP : Time/div. switch from 0.2s to 5ms,
  ALT : Time/div. switch from 2ms to 1μs)
- Deflection factor (normal) : 5mV/div. to 5V/div. in 10 calibrated steps of 1-2-5
  sequence. Continuously variable between steps at least 1:2.5 X 5.
- Deflection factor (5MAG) : 1mV/div. to 1V/div. in 10 calibrated steps.
- Accuracy : normal ±3%, magnified : ±5%
- Input impedance : approx. 1MΩ in parallel with 25pF
- Maximum input voltage : direct 250V (DC + peak AC)
- Input coupling : AC, GND, DC
- Rise time : 5.8ns or less (23ns or less in 5MAG)
- CH1 output : 20mV/div. into 50Ω / DC to 10MHz(-3dB)
- Polarity inversion : CH2 only
- Signal delay : delay cable installed
    HORIZONTAL
    DEFLECTION
- Sweep mode : A, A int B, B, B triggered, X-Y
- Time base A : 0.1μs/div. to 0.2s/div. in 20 calibrated steps of 1-2-5 sequence
  uncalibrated continuous control between steps at least 1:2.5
- Hold-off time on time base A : variable with the hold-off control
- Time base B : 0.1μs/div. to 10μs/div. in 7 calibrated steps of 1-2-5 sequence
- Delay sweep on time base B : 1div. or less / 10 div. or more
- Delay time jitter on time base B : better than 1:20000
- Sweep magnification : 10 times(maximum sweep rate : 20ns/div.)
- Accuracy : ±3%, ±5%(0℃~50℃) / additional error for magnifier : ±2%
    TRIGGER
     SYSTEM
- Modes : AUTO, NORM, TV-V, TV-H
- Source : CH1, CH2, LINE, EXT
- Coupling : AC
- Slope : + or -
- Sensitivity and frequency in AUTO, NORM 20HZ - 2MHz :
   0.5div. in INT / 0.15Vp-p in EXT
- Sensitivity and frequency in AUTO, NORM 2Hz - 60MHz :
   1.5div. in INT / 0.3Vp-p in EXT
- TV-V, TV-H : at least 1div. or 1.0Vp-p
- External trigger input impedance :
  1MΩ in parallel with approx. 30pF
- Maximum input voltage : 250V (DC + AC peak)
X-Y OPERATION
- Sensitivity : same as vertical deflection for both X-axis(CH1)
   except accuracy ± 5% in X-axis
- X-axis bandwidth : DC to 500kHz (-3dB)
- X-Y phase difference : 3° or less as DC to 50kHz
CALIBRATOR
- Probe adjustment : approx. 1kHz frequency, 0.5V(± 3%) square wave with
  50% duty ratio
POWER SUPPLY
- Line voltage range : 100V(90-110V) with 250V 2A fuse, 120V(108-132V) with
  250V 2A fuse, 220V(198-242V) with 250V 1A fuse or 230V(216-250V) with 250V
  1A fuse
- Line frequency : 50/60Hz
- Power consumption : approx. 45W
PHYSICAL CHARACTERISTICS
- Weight : 6.0kg
- Dimension : 320mm(W) X 140mm(H) X 430mm(L)
OTHERS
- Accessories including : Operation manual, Spare fuse, Power cord
- Optional accessories (sold separately) : Probe